Adams Burner Specs

 

ADAMS Gas Burners - Ratings & Specifications

MODEL HU & HA - Gas Conversion Burners for Oil Furnaces & Boilers

Capacity Range: 50,000 to 290,000 Btu/hr. Natural Gas HU_Dim.gif (16117 bytes)
Gas Input Btu/hr Gas Input KW Shipping Dimensions
MODEL Max. Min. Max. Min. Height Width Depth Weight
Constant Pilot, 24 Volt or Self-powered Controls Inches Inches Inches Lbs.
HU-300
Upshot
290,000 50,000 85 15 14 14 24 20 HA_Dim.gif (17377 bytes)
HA-300
Inshot
290,000 50,000 85 15 12 14 24 20
Notes:  A. Gas Saver model available - pilot lit only during call for heat.
B. Upshot model available for LP Gas firing - Max. input 250,000 Btu/hr.

MODEL HP - Spacesaver/Gas Saver Power Gas Burners

Capacity Range: 50,000 to 400,000 Btu/hr. HP_225_Dim.gif (20092 bytes)
Gas Input Btu/hr Gas Input KW Shipping Dimensions
MODEL Max. Min. Max. Min. Height Width Depth Weight
Spacesaver: Constant Pilot - Push button spark pilot igniter Inches Inches Inches Lbs.
HP-225 225,000   50,000   66 15 17 24 18 30
HP-400 400,000 100,000 117 30 18 24 24 35
Gas Saver: Intermittent Pilot - Pilot on only during heating cycle HP_300_Dim.gif (17692 bytes)
HP-225BPS 225,000   50,000   66 15 17 24 18 30
HP-400BPS 400,000 100,000 117 30 18 24 24 35
  Note: Above Models also available for Propane Gas.

HP Series - Forced Draft Gas Burners

Capacity Range: 300,000 to 1,000,000 Btu/hr. HP_800_Dim.gif (19502 bytes)
Gas Input Btu/hr Gas Input KW Shipping Dimensions
MODEL Max. Min. Max. Min. Height Width Depth Weight
Intermittent Pilot - Spark Ignited Pilot, Electronic Relay Inches Inches Inches Lbs.
Natural Gas
HP-800 800,000 300,000   235   90 25 24 26   90
HP-1000 1,000,000 300,000   300   90 25 24 26   90
HP-1500 1,700,000 500,000   500 150 26 24 26   95 HP_2500_Dim.gif (19809 bytes)
HP-2500 2,500,000 1,000,000   735 300 30 26 34 160
HP-3500 3,500,000 1,000,000 1025 300 30 26 34 200
Propane Gas
HP-1000LP 1,000,000 300,000   300   90 25 24 26   90
HP-1500LP 1,700,000 500,000   500 150 26 24 26 105
HP-2500LP 2,500,000 1,000,000   735 300 30 26 34 130

MODEL G2T - Power Gas Burners

Capacity Range: 50,000 to 850,000 Btu/hr.
Gas Input Btu/hr Gas Input KW Shipping Dimensions
MODEL Max. Min. Max. Min. Height Width Depth Weight
Intermittent Pilot - Spark Ignited Pilot, Electronic Relay Inches Inches Inches Lbs.
Natural Gas
G2T-300 300,000 50,000 90 15 20 15 20 40
G2T-600 600,000 50,000 180 15 20 15 20 40
G2T-850 850,000 200,000 250 60 20 15 20 40
Propane Gas
G2T-400LP 400,000 50,000 117 15 20 15 20 40
G2T-850LP 850,000 200,000 250 60 20 15 20 40
 

ALEX BAUER & COMPANY

ESTABLISHED IN 1945

2429 Vauxhall Road • Union, NJ 07083 USA
Tel: 908-964-4042 • Fax: 908-688-6668 • E-Mail: Export@cs123.com

Send mail to WebmasterAB@cs123.com with corrections or comments about this web site.
Website last modified:    Saturday January 08, 2005